Firefighting.

Professional Firefighting

Firefighting equipment materials should be used only with certified products, and firefighting equipment constructed in clean rooms is not easy to inspect and manage, so more professional construction is required.

Sprinkler construction

Criteria for installing sprinklers

Sprinkler installation standards exist to minimize human and property damage in the event of a fire and to prevent the spread of fire through initial suppression.
Logistics terminal among sales facilities, transportation facilities, and warehouse facilities

The number of floors is 3 or more. All floors are 6,000 m or higher.
The number of floors is 4 or higher. All floors are 5,000 m2 or higher.

Among medical facilities, general medical institutions, elderly facilities, and training facilities for accommodation

All floors above 600m2

Cultural and assembly facilities, religious facilities, and sports facilities (excluding zoos, botanical gardens, temples, ancestral rites, shrines, and water play facilities)

Number of people: 100 or more.
The floor area used for movie theaters.
Underground floor or windowless floor: All floors above 500 m2.
In the case of other floors: All floors over 1,000 m2

If you’re one the basement floor, the floor without windows

the floor above 4 floors, all floors above 300 m2. The entire floor of 500 m2 or higher If not.
A rack-type warehouse with a ceiling or a height of more than 10m (a device for transporting a storage by a shelf or elevator)

Among medical facilities, mental medical institutions, elderly facilities, and training facilities for accommodation

All floors above 600 m2
More than 1,000 m2 in the basement (excluding tunnels)

The floor area (excluding frozen warehouses and livestock houses) which is the basement floor, the windowless floor, or the 4th floor as specific firefighting targets

Above 1,000 m2

Dormitory or complex building for accommodation of students in educational research facilities and training facilities

All floors above 5,500 m2

Campuses and military facilities

Shelter, prison, detention center, juvenile center.
Protection facilities (in the case of foreign shelters, it is limited to the living space of the ward)
Except in cases where the protection facility is in the leased building

Firefighting facility construction

Alarm equipment construction
  • Automation re-detection equipment
  • Emergency broadcasting equipment
  • Emergency warning equipment
  • Automation breaking news facility
  • Short circuit alarm
Fire extinguishing equipment construction
  • Indoor fire hydrant
  • Outdoor fire hydrant
  • Sprinkler equipment
  • Water-spray type fire extinguishing equipment
  • Foam Fire Extinguishing equipment
  • Carbon dioxide fire extinguishing equipment.
  • Halogen compound fire extinguishing equipment
  • Powder fire extinguishing equipment
Fire Extinguishing Activity Facility Construction
  • Smoke-free equipment
  • Connection to the water supply pipe
  • Connection to the water supply facility
  • Emergency outlet facilities
  • Wireless communication equipment
  • Combustion prevention equipment
Evacuation Facility Construction
  • Evacuation equipment
  • A life-saving device
  • Exit light/ Exit Sign
  • Emergency lighting
Firefighting Equipment Construction
  • Sprinkler equipment
  • Earthquake-related facilities
  • In/Outdoor fire hydrant facilities
  • And other fire extinguishing facilities
Evacuation Facility Construction
  • Exit Light
  • Evacuation equipment construction
Alarm Equipment Construction
  • Emergency broadcast/alarm
  • Automatic Fire alarm system
  • Automation re-detection equipment